debugserver takes the address of a watchpoint exception and calculates which watchpoint was responsible for it. There was an off-by-one error in the range calculation which causes two watchpoints on consecutive ranges to not correctly identify hits to the second watchpoint. The result is that lldb wouldn't show the second watchpoint as ever being hit. Re-landing this test with a modification to only require two watchpoints in the test, instead of four. If four watchpoints can be set, it will test them. rdar://145107575
97 lines
3.5 KiB
Python
97 lines
3.5 KiB
Python
"""
|
|
Watch contiguous memory regions with separate watchpoints, check that lldb
|
|
correctly detect which watchpoint was hit for each one.
|
|
"""
|
|
|
|
import lldb
|
|
from lldbsuite.test.decorators import *
|
|
from lldbsuite.test.lldbtest import *
|
|
from lldbsuite.test import lldbutil
|
|
|
|
|
|
class ConsecutiveWatchpointsTestCase(TestBase):
|
|
NO_DEBUG_INFO_TESTCASE = True
|
|
|
|
def continue_and_report_stop_reason(self, process, iter_str):
|
|
process.Continue()
|
|
self.assertIn(
|
|
process.GetState(), [lldb.eStateStopped, lldb.eStateExited], iter_str
|
|
)
|
|
thread = process.GetSelectedThread()
|
|
return thread.GetStopReason()
|
|
|
|
# debugserver only gained the ability to watch larger regions
|
|
# with this patch.
|
|
def test_consecutive_watchpoints(self):
|
|
"""Test watchpoint that covers a large region of memory."""
|
|
self.build()
|
|
self.main_source_file = lldb.SBFileSpec("main.c")
|
|
(target, process, thread, bkpt) = lldbutil.run_to_source_breakpoint(
|
|
self, "break here", self.main_source_file
|
|
)
|
|
|
|
frame = thread.GetFrameAtIndex(0)
|
|
|
|
field2_wp = (
|
|
frame.locals["var"][0]
|
|
.GetChildMemberWithName("field2")
|
|
.Watch(True, False, True)
|
|
)
|
|
field3_wp = (
|
|
frame.locals["var"][0]
|
|
.GetChildMemberWithName("field3")
|
|
.Watch(True, False, True)
|
|
)
|
|
field4_wp = (
|
|
frame.locals["var"][0]
|
|
.GetChildMemberWithName("field4")
|
|
.Watch(True, False, True)
|
|
)
|
|
field5_wp = (
|
|
frame.locals["var"][0]
|
|
.GetChildMemberWithName("field5")
|
|
.Watch(True, False, True)
|
|
)
|
|
|
|
# Require that the first two watchpoints
|
|
# are set -- hopefully every machine running
|
|
# the testsuite can support two watchpoints.
|
|
self.assertTrue(field2_wp.IsValid())
|
|
self.assertTrue(field3_wp.IsValid())
|
|
|
|
reason = self.continue_and_report_stop_reason(process, "continue to field2 wp")
|
|
self.assertEqual(reason, lldb.eStopReasonWatchpoint)
|
|
stop_reason_watchpoint_id = (
|
|
process.GetSelectedThread().GetStopReasonDataAtIndex(0)
|
|
)
|
|
self.assertEqual(stop_reason_watchpoint_id, field2_wp.GetID())
|
|
|
|
reason = self.continue_and_report_stop_reason(process, "continue to field3 wp")
|
|
self.assertEqual(reason, lldb.eStopReasonWatchpoint)
|
|
stop_reason_watchpoint_id = (
|
|
process.GetSelectedThread().GetStopReasonDataAtIndex(0)
|
|
)
|
|
self.assertEqual(stop_reason_watchpoint_id, field3_wp.GetID())
|
|
|
|
# If we were able to set the second two watchpoints,
|
|
# check that they are hit. Some CI bots can only
|
|
# create two watchpoints.
|
|
if field4_wp.IsValid() and field5_wp.IsValid():
|
|
reason = self.continue_and_report_stop_reason(
|
|
process, "continue to field4 wp"
|
|
)
|
|
self.assertEqual(reason, lldb.eStopReasonWatchpoint)
|
|
stop_reason_watchpoint_id = (
|
|
process.GetSelectedThread().GetStopReasonDataAtIndex(0)
|
|
)
|
|
self.assertEqual(stop_reason_watchpoint_id, field4_wp.GetID())
|
|
|
|
reason = self.continue_and_report_stop_reason(
|
|
process, "continue to field5 wp"
|
|
)
|
|
self.assertEqual(reason, lldb.eStopReasonWatchpoint)
|
|
stop_reason_watchpoint_id = (
|
|
process.GetSelectedThread().GetStopReasonDataAtIndex(0)
|
|
)
|
|
self.assertEqual(stop_reason_watchpoint_id, field5_wp.GetID())
|