This corrects a couple off by ones related to the sampling of **instrumented** counters, and enables setting 100% rates for burst sampling (burst duration = period). Off by ones: Prior to this change it was impossible to set a period of 65535 because this was converted to fast sampling which rollsover at USHRT_MAX + 1 (65536). Similarly the burst durations would collect burst duration + 1 counts as they used an ULE comparison. 100% sampling: Although this is not useful for a productionized use case, it does allow for more deterministic testing with the sampling checks in place. After all the off by ones are fixed, allowing for 100% sampling is a matter of letting burst duration = period.