MI300 ISA section 4.5 states there is a hazard between "VALU op which uses OPSEL or SDWA with changes the result’s bit position" and "VALU op consumes result of that op" This includes the case where the second op is SDWA with same dest and dst_sel != DWORD && dst_unused == UNUSED_PRESERVE. In this case, there is an implicit read of the first op dst and the compiler needs to resolve this hazard. Confirmed with HW team. We model dst_unused == UNUSED_PRESERVE as tied-def of implicit operand, so this PR checks for that. MI300_SP_MAS section 1.3.9.2 specifies that CVT_SR_FP8_F32 and CVT_SR_BF8_F32 with opsel[3:2] !=0 have dest forwarding issue. Currently, we only add check for CVT_SR_FP8_F32 with opsel[3] != 0 -- this PR adds support opsel[2] != 0 as well